{"id":1473,"date":"2025-10-15T10:58:03","date_gmt":"2025-10-15T02:58:03","guid":{"rendered":"https:\/\/medicaladaptertech.com\/?post_type=product&#038;p=1473"},"modified":"2026-04-20T11:49:12","modified_gmt":"2026-04-20T03:49:12","slug":"serie-de-65-vatios-intercambiables","status":"publish","type":"product","link":"https:\/\/medicaladaptertech.com\/es\/product\/65-watt-series-changeable\/","title":{"rendered":"Serie de 65 vatios intercambiable"},"content":{"rendered":"<div data-elementor-type=\"product-post\" data-elementor-id=\"1473\" class=\"elementor elementor-1473\" data-elementor-post-type=\"product\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3b46d879 e-flex e-con-boxed e-con e-parent\" data-id=\"3b46d879\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-bf8365e elementor-widget elementor-widget-heading\" data-id=\"bf8365e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Modelo de salida:<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c66fa06 elementor-widget elementor-widget-eael-advanced-data-table\" data-id=\"c66fa06\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"eael-advanced-data-table.default\">\n\t\t\t\t\t<div class=\"ea-advanced-data-table-wrap\" data-id=\"c66fa06\"><div class=\"ea-advanced-data-table-wrap-inner\">\n                <table class=\"ea-advanced-data-table ea-advanced-data-table-csv ea-advanced-data-table-c66fa06 ea-advanced-data-table-sortable\" data-id=\"c66fa06\"><thead><tr><th>Modelo<\/th><th>Voltaje de salida<\/th><th>Corriente de salida<\/th><th>Vato<\/th><\/tr><\/thead><tbody><tr><td>ATM065A4-W120<\/td><td>12,0 V<\/td><td>5,00 A<\/td><td>60,0 W<\/td><\/tr><tr><td>ATM065A4-W150<\/td><td>15,0 V<\/td><td>4,34 A<\/td><td>65,0 W<\/td><\/tr><tr><td>ATM065A4-W190<\/td><td>19,0 V<\/td><td>3,43 A<\/td><td>65,0 W<\/td><\/tr><tr><td>ATM065A4-W240<\/td><td>24,0 V<\/td><td>2,71 A<\/td><td>65,0 W<\/td><\/tr><tr><td>ATM065A4-W480<\/td><td>48,0 V<\/td><td>1,36 A<\/td><td>65,0 W<\/td><\/tr><\/tbody><\/table>\n            <\/div><\/div>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-61afcc6 elementor-widget elementor-widget-heading\" data-id=\"61afcc6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Entrada:<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8890c3e elementor-widget elementor-widget-eael-advanced-data-table\" data-id=\"8890c3e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"eael-advanced-data-table.default\">\n\t\t\t\t\t<div class=\"ea-advanced-data-table-wrap\" data-id=\"8890c3e\"><div class=\"ea-advanced-data-table-wrap-inner\">\n                <table class=\"ea-advanced-data-table ea-advanced-data-table-csv ea-advanced-data-table-8890c3e\" data-id=\"8890c3e\"><thead><tr><th>Entrada<\/th><th><\/th><\/tr><\/thead><tbody><tr><td>Voltaje<\/td><td>100-240 VCA<\/td><\/tr><tr><td>Frecuencia de l\u00ednea<\/td><td>50-60 Hz<\/td><\/tr><tr><td>Actual<\/td><td>1,6 A - 0,7 A<\/td><\/tr><tr><td>Protecci\u00f3n<\/td><td>Fusible interno de corriente primaria<\/td><\/tr><\/tbody><\/table>\n            <\/div><\/div>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5f72b65 elementor-widget elementor-widget-heading\" data-id=\"5f72b65\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Salida:<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6a79eaa elementor-widget elementor-widget-eael-advanced-data-table\" data-id=\"6a79eaa\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"eael-advanced-data-table.default\">\n\t\t\t\t\t<div class=\"ea-advanced-data-table-wrap\" data-id=\"6a79eaa\"><div class=\"ea-advanced-data-table-wrap-inner\">\n                <table class=\"ea-advanced-data-table ea-advanced-data-table-csv ea-advanced-data-table-6a79eaa\" data-id=\"6a79eaa\"><thead><tr><th>salida<\/th><th><\/th><\/tr><\/thead><tbody><tr><td>Regulaci\u00f3n de carga<\/td><td>\u00b1 5% (t\u00edpico)<\/td><\/tr><tr><td>Ondulaci\u00f3n y ruido<\/td><td>\u2264 21 TP3T Vp-p a plena carga<\/td><\/tr><tr><td>Respuesta transitoria (din\u00e1mica)<\/td><td>0,5 ms con cambio de carga 50%<\/td><\/tr><tr><td>Tiempo de arranque<\/td><td>&lt; 3000 ms<\/td><\/tr><tr><td>Tiempo de espera<\/td><td>\u2265 10 ms a plena carga<\/td><\/tr><tr><td>Tiempo de subida<\/td><td>&lt; 50 ms<\/td><\/tr><tr><td>Protecci\u00f3n<\/td><td>Protecci\u00f3n contra cortocircuitos\/Protecci\u00f3n contra sobretensi\u00f3n\/Protecci\u00f3n contra sobrecorriente<\/td><\/tr><\/tbody><\/table>\n            <\/div><\/div>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c808296 elementor-widget elementor-widget-heading\" data-id=\"c808296\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">El\u00e9ctrico:<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c6742d8 elementor-widget elementor-widget-eael-advanced-data-table\" data-id=\"c6742d8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"eael-advanced-data-table.default\">\n\t\t\t\t\t<div class=\"ea-advanced-data-table-wrap\" data-id=\"c6742d8\"><div class=\"ea-advanced-data-table-wrap-inner\">\n                <table class=\"ea-advanced-data-table ea-advanced-data-table-csv ea-advanced-data-table-c6742d8\" data-id=\"c6742d8\"><thead><tr><th>El\u00e9ctrico<\/th><th><\/th><\/tr><\/thead><tbody><tr><td>Resistencia diel\u00e9ctrica<\/td><td>4000 VCA Primario - Secundario<\/td><\/tr><tr><td>Corriente de contacto (paciente) Corriente de fuga<\/td><td>&lt; 100 \u03bcA<\/td><\/tr><tr><td>Eficiencia<\/td><td>Cumple con el nivel VI del Departamento de Energ\u00eda, la fase 2 de ErP y el nivel 2 de CoC.<\/td><\/tr><tr><td>Normas EMC<\/td><td>EN55011<br>EN 61000-3-2,3<br>EN 61000-4-2, 3, 4, 5, 6, 8, 11<\/td><\/tr><tr><td>MTBF<\/td><td>300 000 horas calculadas a 25 \u00b0C, seg\u00fan Telcordia SR-332.<\/td><\/tr><\/tbody><\/table>\n            <\/div><\/div>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b583009 elementor-widget elementor-widget-heading\" data-id=\"b583009\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Medioambiental:<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-fb59128 elementor-widget elementor-widget-eael-advanced-data-table\" data-id=\"fb59128\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"eael-advanced-data-table.default\">\n\t\t\t\t\t<div class=\"ea-advanced-data-table-wrap\" data-id=\"fb59128\"><div class=\"ea-advanced-data-table-wrap-inner\">\n                <table class=\"ea-advanced-data-table ea-advanced-data-table-csv ea-advanced-data-table-fb59128\" data-id=\"fb59128\"><thead><tr><th>Medioambiental<\/th><th><\/th><\/tr><\/thead><tbody><tr><td>Temperatura de funcionamiento<\/td><td>-20 a +40 \u00b0C,<\/td><\/tr><tr><td>Temperatura de almacenamiento<\/td><td>-20 a + 80 \u00b0C,<\/td><\/tr><tr><td>Altitud operativa<\/td><td>5000 m<\/td><\/tr><tr><td>Humedad relativa<\/td><td>Funcionamiento: 20 a 80% RH<br>Almacenamiento: 10 a 90% RH<\/td><\/tr><tr><td>Refrigeraci\u00f3n<\/td><td>Refrigeraci\u00f3n por convecci\u00f3n natural<\/td><\/tr><\/tbody><\/table>\n            <\/div><\/div>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-138ce3a elementor-widget elementor-widget-heading\" data-id=\"138ce3a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Mec\u00e1nico:<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-fcb4b1d elementor-widget elementor-widget-eael-advanced-data-table\" data-id=\"fcb4b1d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"eael-advanced-data-table.default\">\n\t\t\t\t\t<div class=\"ea-advanced-data-table-wrap\" data-id=\"fcb4b1d\"><div class=\"ea-advanced-data-table-wrap-inner\">\n                <table class=\"ea-advanced-data-table ea-advanced-data-table-csv ea-advanced-data-table-fcb4b1d\" data-id=\"fcb4b1d\"><thead><tr><th>Mec\u00e1nico<\/th><th><\/th><\/tr><\/thead><tbody><tr><td>Dimensiones de la caja<\/td><td>53,5 cm (largo) x 31,5 cm (ancho) x 74,5 cm (alto) (mm)<\/td><\/tr><tr><td>Peso<\/td><td>195 g (Ref.)<\/td><\/tr><\/tbody><\/table>\n            <\/div><\/div>\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-409295b elementor-widget elementor-widget-image\" data-id=\"409295b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"800\" height=\"524\" src=\"https:\/\/medicaladaptertech.com\/wp-content\/uploads\/2025\/10\/\u6e29\u5ea6\u56fe\u7247-P1-4873-74-1024x671.jpg\" class=\"attachment-large size-large wp-image-908\" alt=\"\" srcset=\"https:\/\/medicaladaptertech.com\/wp-content\/uploads\/2025\/10\/\u6e29\u5ea6\u56fe\u7247-P1-4873-74-1024x671.jpg 1024w, https:\/\/medicaladaptertech.com\/wp-content\/uploads\/2025\/10\/\u6e29\u5ea6\u56fe\u7247-P1-4873-74-300x197.jpg 300w, https:\/\/medicaladaptertech.com\/wp-content\/uploads\/2025\/10\/\u6e29\u5ea6\u56fe\u7247-P1-4873-74-768x503.jpg 768w, https:\/\/medicaladaptertech.com\/wp-content\/uploads\/2025\/10\/\u6e29\u5ea6\u56fe\u7247-P1-4873-74-1536x1006.jpg 1536w, https:\/\/medicaladaptertech.com\/wp-content\/uploads\/2025\/10\/\u6e29\u5ea6\u56fe\u7247-P1-4873-74.jpg 1920w, https:\/\/medicaladaptertech.com\/wp-content\/uploads\/2025\/10\/\u6e29\u5ea6\u56fe\u7247-P1-4873-74-800x524.jpg 800w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-dce0234 elementor-widget elementor-widget-heading\" data-id=\"dce0234\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Perfil de Dilithink<\/h2>\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-f0922e4 e-con-full e-flex e-con e-child\" data-id=\"f0922e4\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-60737c55 e-con-full e-flex e-con e-child\" data-id=\"60737c55\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-58903b4e elementor-widget elementor-widget-text-editor\" data-id=\"58903b4e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t\t\t\t\t\t<p>Dilithink es un fabricante OEM\/ODM especializado en soluciones de alimentaci\u00f3n m\u00e9dica seguras y estables.<\/p><p>Nos centramos en adaptadores CA\/CC, incluida la tecnolog\u00eda GaN de vanguardia para una potencia ultracompacta y de alta densidad.<\/p><p>Todos los productos cumplen con los m\u00e1s altos est\u00e1ndares de seguridad con aislamiento 2X MOPP y cuentan con certificaci\u00f3n internacional (IEC\/UL 60601-1). Elija Dilithink para obtener una fuente de alimentaci\u00f3n fiable en la atenci\u00f3n a pacientes cr\u00edticos.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-27da8108 e-con-full e-flex e-con e-child\" data-id=\"27da8108\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-e16e3dd elementor--h-position-center elementor--v-position-middle elementor-arrows-position-inside elementor-pagination-position-inside elementor-widget elementor-widget-slides\" data-id=\"e16e3dd\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;navigation&quot;:&quot;both&quot;,&quot;autoplay&quot;:&quot;yes&quot;,&quot;pause_on_hover&quot;:&quot;yes&quot;,&quot;pause_on_interaction&quot;:&quot;yes&quot;,&quot;autoplay_speed&quot;:5000,&quot;infinite&quot;:&quot;yes&quot;,&quot;transition&quot;:&quot;slide&quot;,&quot;transition_speed&quot;:500}\" data-widget_type=\"slides.default\">\n\t\t\t\t\t\t\t\t\t\t<div class=\"elementor-slides-wrapper elementor-main-swiper swiper\" role=\"region\" aria-roledescription=\"carousel\" aria-label=\"Diapositivas\" dir=\"ltr\" data-animation=\"fadeInUp\">\n\t\t\t\t<div class=\"swiper-wrapper elementor-slides\">\n\t\t\t\t\t\t\t\t\t\t<div class=\"elementor-repeater-item-2057e18 swiper-slide\" role=\"group\" aria-roledescription=\"slide\"><div class=\"swiper-slide-bg\" role=\"img\" aria-label=\"Prueba de salida_\"><\/div><div class=\"swiper-slide-inner\" ><div class=\"swiper-slide-contents\"><\/div><\/div><\/div><div class=\"elementor-repeater-item-fccd141 swiper-slide\" role=\"group\" aria-roledescription=\"slide\"><div class=\"swiper-slide-bg\" role=\"img\" aria-label=\"Impresi\u00f3n l\u00e1ser_\"><\/div><div class=\"swiper-slide-inner\" ><div class=\"swiper-slide-contents\"><\/div><\/div><\/div><div class=\"elementor-repeater-item-7fbcab2 swiper-slide\" role=\"group\" aria-roledescription=\"slide\"><div class=\"swiper-slide-bg\" role=\"img\" aria-label=\"Taller sobre el envejecimiento\"><\/div><div class=\"swiper-slide-inner\" ><div class=\"swiper-slide-contents\"><\/div><\/div><\/div>\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<div class=\"elementor-swiper-button elementor-swiper-button-prev\" role=\"button\" tabindex=\"0\" aria-label=\"Diapositiva anterior\" data-no-translation-aria-label=\"\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-eicon-chevron-left\" viewbox=\"0 0 1000 1000\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M646 125C629 125 613 133 604 142L308 442C296 454 292 471 292 487 292 504 296 521 308 533L604 854C617 867 629 875 646 875 663 875 679 871 692 858 704 846 713 829 713 812 713 796 708 779 692 767L438 487 692 225C700 217 708 204 708 187 708 171 704 154 692 142 675 129 663 125 646 125Z\"><\/path><\/svg>\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t<div class=\"elementor-swiper-button elementor-swiper-button-next\" role=\"button\" tabindex=\"0\" aria-label=\"Diapositiva siguiente\" data-no-translation-aria-label=\"\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-eicon-chevron-right\" viewbox=\"0 0 1000 1000\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M696 533C708 521 713 504 713 487 713 471 708 454 696 446L400 146C388 133 375 125 354 125 338 125 325 129 313 142 300 154 292 171 292 187 292 204 296 221 308 233L563 492 304 771C292 783 288 800 288 817 288 833 296 850 308 863 321 871 338 875 354 875 371 875 388 867 400 854L696 533Z\"><\/path><\/svg>\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<div class=\"swiper-pagination\"><\/div>\n\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>. IEC\/EN\/ANSI\/AAMI ES60601-1 (Edici\u00f3n 3.2)<\/p>\n<p>. EMC: IEC 60601-1-2 (Edici\u00f3n 4.1)<\/p>\n<p>. Medios de protecci\u00f3n: 2 X MOPP<\/p>\n<p>. Corriente de fuga &lt; 100 \u00b5A<\/p>\n<p>. Salida regulada con bajo ruido de ondulaci\u00f3n<\/p>\n<p>. Requisitos de la agencia de seguridad y certificaci\u00f3n EMI\/EMS.<\/p>\n<p>. Dise\u00f1o modificado y personalizado disponible.<\/p>","protected":false},"featured_media":1474,"template":"","meta":{"_acf_changed":false},"product_brand":[],"product_cat":[39],"product_tag":[90,110,99,149,107],"class_list":["post-1473","product","type-product","status-publish","has-post-thumbnail","product_cat-external-medical-power-supply","product_tag-65w","product_tag-interchangeable-plug","product_tag-medical-adapter","product_tag-medical-interchangeable-plug","product_tag-medical-wall-mount-power-adapter","first","instock","shipping-taxable","product-type-simple"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.5 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>OEM 65W Changeable Medical Adapter | 2xMOPP | Dilithink<\/title>\n<meta name=\"description\" content=\"Source high-power 65W interchangeable medical adapters from our factory. Eliminate power cords with global AC plugs, 2xMOPP safety, and &lt;100\u03bcA leakage.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/medicaladaptertech.com\/es\/product\/serie-de-65-vatios-intercambiables\/\" \/>\n<meta property=\"og:locale\" content=\"es_ES\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"OEM 65W Changeable Medical Adapter | 2xMOPP | Dilithink\" \/>\n<meta property=\"og:description\" content=\"Source high-power 65W interchangeable medical adapters from our factory. Eliminate power cords with global AC plugs, 2xMOPP safety, and &lt;100\u03bcA leakage.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/medicaladaptertech.com\/es\/product\/serie-de-65-vatios-intercambiables\/\" \/>\n<meta property=\"og:site_name\" content=\"Dilithink\" \/>\n<meta property=\"article:modified_time\" content=\"2026-04-20T03:49:12+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/medicaladaptertech.com\/wp-content\/uploads\/2025\/10\/65W-ATM065A4-1.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"800\" \/>\n\t<meta property=\"og:image:height\" content=\"800\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Tiempo de lectura\" \/>\n\t<meta name=\"twitter:data1\" content=\"2 minutos\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/medicaladaptertech.com\\\/product\\\/65-watt-series-changeable\\\/\",\"url\":\"https:\\\/\\\/medicaladaptertech.com\\\/product\\\/65-watt-series-changeable\\\/\",\"name\":\"OEM 65W Changeable Medical Adapter | 2xMOPP | Dilithink\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/medicaladaptertech.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/medicaladaptertech.com\\\/product\\\/65-watt-series-changeable\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/medicaladaptertech.com\\\/product\\\/65-watt-series-changeable\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/medicaladaptertech.com\\\/wp-content\\\/uploads\\\/2025\\\/10\\\/65W-ATM065A4-1.jpg\",\"datePublished\":\"2025-10-15T02:58:03+00:00\",\"dateModified\":\"2026-04-20T03:49:12+00:00\",\"description\":\"Source high-power 65W interchangeable medical adapters from our factory. Eliminate power cords with global AC plugs, 2xMOPP safety, and &lt;100\u03bcA leakage.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/medicaladaptertech.com\\\/product\\\/65-watt-series-changeable\\\/#breadcrumb\"},\"inLanguage\":\"es\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/medicaladaptertech.com\\\/product\\\/65-watt-series-changeable\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\\\/\\\/medicaladaptertech.com\\\/product\\\/65-watt-series-changeable\\\/#primaryimage\",\"url\":\"https:\\\/\\\/medicaladaptertech.com\\\/wp-content\\\/uploads\\\/2025\\\/10\\\/65W-ATM065A4-1.jpg\",\"contentUrl\":\"https:\\\/\\\/medicaladaptertech.com\\\/wp-content\\\/uploads\\\/2025\\\/10\\\/65W-ATM065A4-1.jpg\",\"width\":800,\"height\":800,\"caption\":\"65W Interchangeable Medical Adapter | Multi-Plug 2X MOPP PSU OEM Factory\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/medicaladaptertech.com\\\/product\\\/65-watt-series-changeable\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/medicaladaptertech.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Product\",\"item\":\"https:\\\/\\\/medicaladaptertech.com\\\/product\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"External Medical Power Supply\",\"item\":\"https:\\\/\\\/medicaladaptertech.com\\\/product-category\\\/external-medical-power-supply\\\/\"},{\"@type\":\"ListItem\",\"position\":4,\"name\":\"65 Watt Series Changeable\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/medicaladaptertech.com\\\/#website\",\"url\":\"https:\\\/\\\/medicaladaptertech.com\\\/\",\"name\":\"Dilithink\",\"description\":\"Precision Power Supply for Advanced Medical Devices\",\"publisher\":{\"@id\":\"https:\\\/\\\/medicaladaptertech.com\\\/#organization\"},\"alternateName\":\"Dilithink\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/medicaladaptertech.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"es\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/medicaladaptertech.com\\\/#organization\",\"name\":\"Dilithink\",\"alternateName\":\"SHENZHEN DILITHINK ELECTRONICS CO.,LTD.\",\"url\":\"https:\\\/\\\/medicaladaptertech.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\\\/\\\/medicaladaptertech.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/medicaladaptertech.com\\\/wp-content\\\/uploads\\\/2025\\\/11\\\/DILITHINK-LOGO1_00.png\",\"contentUrl\":\"https:\\\/\\\/medicaladaptertech.com\\\/wp-content\\\/uploads\\\/2025\\\/11\\\/DILITHINK-LOGO1_00.png\",\"width\":709,\"height\":354,\"caption\":\"Dilithink\"},\"image\":{\"@id\":\"https:\\\/\\\/medicaladaptertech.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"OEM 65W Changeable Medical Adapter | 2xMOPP | Dilithink","description":"Source high-power 65W interchangeable medical adapters from our factory. Eliminate power cords with global AC plugs, 2xMOPP safety, and &lt;100\u03bcA leakage.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/medicaladaptertech.com\/es\/product\/serie-de-65-vatios-intercambiables\/","og_locale":"es_ES","og_type":"article","og_title":"OEM 65W Changeable Medical Adapter | 2xMOPP | Dilithink","og_description":"Source high-power 65W interchangeable medical adapters from our factory. Eliminate power cords with global AC plugs, 2xMOPP safety, and &lt;100\u03bcA leakage.","og_url":"https:\/\/medicaladaptertech.com\/es\/product\/serie-de-65-vatios-intercambiables\/","og_site_name":"Dilithink","article_modified_time":"2026-04-20T03:49:12+00:00","og_image":[{"width":800,"height":800,"url":"https:\/\/medicaladaptertech.com\/wp-content\/uploads\/2025\/10\/65W-ATM065A4-1.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Tiempo de lectura":"2 minutos"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/medicaladaptertech.com\/product\/65-watt-series-changeable\/","url":"https:\/\/medicaladaptertech.com\/product\/65-watt-series-changeable\/","name":"OEM 65W Changeable Medical Adapter | 2xMOPP | Dilithink","isPartOf":{"@id":"https:\/\/medicaladaptertech.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/medicaladaptertech.com\/product\/65-watt-series-changeable\/#primaryimage"},"image":{"@id":"https:\/\/medicaladaptertech.com\/product\/65-watt-series-changeable\/#primaryimage"},"thumbnailUrl":"https:\/\/medicaladaptertech.com\/wp-content\/uploads\/2025\/10\/65W-ATM065A4-1.jpg","datePublished":"2025-10-15T02:58:03+00:00","dateModified":"2026-04-20T03:49:12+00:00","description":"Source high-power 65W interchangeable medical adapters from our factory. Eliminate power cords with global AC plugs, 2xMOPP safety, and &lt;100\u03bcA leakage.","breadcrumb":{"@id":"https:\/\/medicaladaptertech.com\/product\/65-watt-series-changeable\/#breadcrumb"},"inLanguage":"es","potentialAction":[{"@type":"ReadAction","target":["https:\/\/medicaladaptertech.com\/product\/65-watt-series-changeable\/"]}]},{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/medicaladaptertech.com\/product\/65-watt-series-changeable\/#primaryimage","url":"https:\/\/medicaladaptertech.com\/wp-content\/uploads\/2025\/10\/65W-ATM065A4-1.jpg","contentUrl":"https:\/\/medicaladaptertech.com\/wp-content\/uploads\/2025\/10\/65W-ATM065A4-1.jpg","width":800,"height":800,"caption":"65W Interchangeable Medical Adapter | Multi-Plug 2X MOPP PSU OEM Factory"},{"@type":"BreadcrumbList","@id":"https:\/\/medicaladaptertech.com\/product\/65-watt-series-changeable\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/medicaladaptertech.com\/"},{"@type":"ListItem","position":2,"name":"Product","item":"https:\/\/medicaladaptertech.com\/product\/"},{"@type":"ListItem","position":3,"name":"External Medical Power Supply","item":"https:\/\/medicaladaptertech.com\/product-category\/external-medical-power-supply\/"},{"@type":"ListItem","position":4,"name":"65 Watt Series Changeable"}]},{"@type":"WebSite","@id":"https:\/\/medicaladaptertech.com\/#website","url":"https:\/\/medicaladaptertech.com\/","name":"Dilithink","description":"Fuente de alimentaci\u00f3n de precisi\u00f3n para dispositivos m\u00e9dicos avanzados","publisher":{"@id":"https:\/\/medicaladaptertech.com\/#organization"},"alternateName":"Dilithink","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/medicaladaptertech.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"es"},{"@type":"Organization","@id":"https:\/\/medicaladaptertech.com\/#organization","name":"Dilithink","alternateName":"SHENZHEN DILITHINK ELECTRONICS CO.,LTD.","url":"https:\/\/medicaladaptertech.com\/","logo":{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/medicaladaptertech.com\/#\/schema\/logo\/image\/","url":"https:\/\/medicaladaptertech.com\/wp-content\/uploads\/2025\/11\/DILITHINK-LOGO1_00.png","contentUrl":"https:\/\/medicaladaptertech.com\/wp-content\/uploads\/2025\/11\/DILITHINK-LOGO1_00.png","width":709,"height":354,"caption":"Dilithink"},"image":{"@id":"https:\/\/medicaladaptertech.com\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/medicaladaptertech.com\/es\/wp-json\/wp\/v2\/product\/1473","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/medicaladaptertech.com\/es\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/medicaladaptertech.com\/es\/wp-json\/wp\/v2\/types\/product"}],"version-history":[{"count":0,"href":"https:\/\/medicaladaptertech.com\/es\/wp-json\/wp\/v2\/product\/1473\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/medicaladaptertech.com\/es\/wp-json\/wp\/v2\/media\/1474"}],"wp:attachment":[{"href":"https:\/\/medicaladaptertech.com\/es\/wp-json\/wp\/v2\/media?parent=1473"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/medicaladaptertech.com\/es\/wp-json\/wp\/v2\/product_brand?post=1473"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/medicaladaptertech.com\/es\/wp-json\/wp\/v2\/product_cat?post=1473"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/medicaladaptertech.com\/es\/wp-json\/wp\/v2\/product_tag?post=1473"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}