Home » Product » Open frame medische voeding » Open frame met dubbele uitgang, 450 watt-serie
| Model | O/P-spanning | O/P Current(Convection) | O/P Current(With Fan) | O/P for Fan | Watt(Convection) | Watt(With Fan) |
|---|---|---|---|---|---|---|
| ATM450S-F120 | 12,0 V | 16,0 A | 25.0A | 12V/0.6A | 260W | 462W |
| ATM450S-F120 | 5,00 V | 1.0A | 1.0A | 12V/0.6A | 260W | 462W |
| ATM450S-F150 | 15,0 V | 16,0 A | 25.0A | 12V/0.6A | 260W | 462W |
| ATM450S-F150 | 5,00 V | 1.0A | 1.0A | 12V/0.6A | 260W | 462W |
| ATM450S-F190 | 19,0 V | 16,0 A | 25.0A | 12V/0.6A | 260W | 462W |
| ATM450S-F190 | 5,00 V | 1.0A | 1.0A | 12V/0.6A | 260W | 462W |
| ATM450S-F240 | 24,0 V | 16,0 A | 25.0A | 12V/0.6A | 260W | 463W |
| ATM450S-F240 | 5,00 V | 1.0A | 1.0A | 12V/0.6A | 260W | 463W |
| ATM450S-F360 | 36,0 V | 16,0 A | 25.0A | 12V/0.6A | 260W | 462W |
| ATM450S-F360 | 5,00 V | 1.0A | 1.0A | 12V/0.6A | 260W | 462W |
| ATM450S-F480 | 48,0 V | 16,0 A | 25.0A | 12V/0.6A | 260W | 463W |
| ATM450S-F480 | 5,00 V | 1.0A | 1.0A | 12V/0.6A | 260W | 463W |
| ATM450S-F540 | 54.0V | 16,0 A | 25.0A | 12V/0.6A | 260W | 460W |
| ATM450S-F540 | 5,00 V | 1.0A | 1.0A | 12V/0.6A | 260W | 460W |
| ATM450S-F560 | 56,0 V | 16,0 A | 25.0A | 12V/0.6A | 260W | 460W |
| ATM450S-F560 | 5,00 V | 1.0A | 1.0A | 12V/0.6A | 260W | 460W |
| Invoer | |
|---|---|
| Spanning | 100-240 VAC |
| Lijnfrequentie | 50-60 Hz |
| Huidig | 5,3 A - 2,2 A |
| Bescherming | Interne primaire stroomzekering |
| output | |
|---|---|
| Belastingsregeling | ± 5% (typisch) |
| Rimpeling en ruis | ≤ 1% Vp-p bij volledige belasting |
| Transiënte (dynamische) respons | 0,5 mS met 50%-belastingsverandering |
| Opstarttijd | < 3000 ms |
| Wachttijd | ≥ 10 mS bij volledige belasting |
| Stijgtijd | < 50 ms |
| Bescherming | Kortsluitbeveiliging/overspanningsbeveiliging/overstroombeveiliging |
| Elektrisch | |
|---|---|
| Diëlektrische weerstand | 4.000 VAC primair - secundair |
| Aanraakstroom (patiënt) Lekstroom | < 100 μA |
| Earth Leakage Curent | < 5mA |
| Efficiëntie | Voldoet aan DoE Level VI, ErP Stage 2, CoC Tier 2 |
| gemiddelde tijd tussen storingen | 300.000 berekende uren bij 25 °C, volgens Telcordia SR-332 |
| Milieu | |
|---|---|
| Bedrijfstemperatuur | -20 tot + 40 °C, |
| Opslagtemperatuur | -20 tot + 80 °C, |
| Bedrijfshoogte | 5000 m |
| Relatieve vochtigheid | Werking: 20 tot 80% RH Opslag: 10 tot 90% RH |
| Koeling | 250W with Forced Cooling 450W with Forced Cooling |
| Mechanisch | |
|---|---|
| Afmeting | Open Frame: L 127 x W 76 x H 34 (mm) 5'' x 3'' x 1.3'' |
| Afmeting | Enclosed Type(Top Fan): L 127 x W 87 x H 50 (mm) 5'' x 3.4'' x 2.0'' |
| Afmeting | Enclosed Type(Side Fan): L 148 x W 80 x H 41 (mm) 5.9'' x 3.2'' x 1.6'' |
| Gewicht | Open Frame: 390g ( Ref. ) Enclosed Type ( Top Fan ) : 570g ( Ref. ) Enclosed Type ( Side Fan ) : 660g ( Ref. ) |
Dilithink is een toegewijde OEM/ODM-fabrikant die gespecialiseerd is in veilige en stabiele medische stroomoplossingen.
Wij richten ons op AC/DC-adapters, waaronder geavanceerde GaN-technologie voor ultracompacte stroomvoorziening met hoge dichtheid.
Alle producten voldoen aan de hoogste veiligheidsnormen met 2X MOPP-isolatie en zijn wereldwijd gecertificeerd (IEC/UL 60601-1). Kies Dilithink voor betrouwbare stroomvoorziening bij kritieke patiëntenzorg.

Op 19 oktober 2021 om 1 uur 's nachts hield Apple een evenement om de Macbook officieel aan te kondigen...

We blijven de ontwikkeling in de opladerindustrie volgen en ontwikkelen de PD30W GaN-oplader 30W...

Inleiding tot de volgende generatie oplaadtechnologie Dilithink heeft officieel een nieuwe generatie stroomoplossing geïntroduceerd door baanbrekend werk te verrichten...

Een traditie van focus: gespecialiseerd in medische en militaire stroomvoorziening Sinds 2001 is Dilithink...